Pt100 sensor for temperature logger
Product code: LOG-PT100-00Pt100 sensor 2 m Cable 100 mm Steel Tips 3.2 mm Diameter
Subcategories
Pt100 sensor 2 m Cable 100 mm Steel Tips 3.2 mm Diameter
Pt100 sensor with 2 m cable and 100 mm probe
5 kanals analog input 2 kanals analog output 2 kanals digital input 2 kanals digital output
Built-in Web server Web HMI Modbus TCP and Modbus UDP protocols Good communication security 1 x RJ45 port Ethernet Dual Watchdog Operating temperature range: -25 to + 75 ° C I / O Pair-connection input is mirrored in the other's output 8 x Analog differential input: output voltage and current +/- 150mV - +/- 10V, 20mA +/- - 0 - 20mA 16-bit resolution, 10 samples per second 4 x Digital outputs - Open Collector, max. 50VDC / 700mA Supply voltage: 10 - 30VDC / 2.8Watt
Ethernet module with 2 digital inputs and 1 relay output 2 x digital dry contact - active high by connecting contact 1 x Power relay, 250vac / 5a, 30vdc / 5a Avoid inductive load to relay P2P Function that reflects an input to other module output Supports Modbus / TCP and UDP Slave Power supplied from PoE or 12 - 48VDC PoE: IEEE802.3af, Class 1 Operating temperature: - 25 - + 75 ° C Dim: 98 x 52 x 27 mm DIN bracket
HMI control with 4.3 "TFT Touch IP40 interface: 2 x RS485 USB port for download RTC - Real Time Clock Free HmiWorks Development software Supply voltage: 12 - 48VDC Temperature: -30 - + 50 ° C Goal: 140 x 87 x 41 mm Less-Surface-Exposed Housing Design Design
ANALOGT INPUT MODUL TIL MODBUS
Ethernet to 6 Channel Isolated Digital Input / 6 Relay Modbus TCP Peer-to-peer fashion
Gateway from Ethernet slave to PROFIBUS master protocol / hierarchy: DP-V0 Slave PROFIBUS Speed (Kbps) in 10 step from 9.6 - 12000 speed setting is automatic Max. Input data length: 240 byte Max. Output data length: 240 bytes Address setting: 0 ~ 126 Set by DIP switch or EEPROM Ethernet protocol: TCP / UDP server / client Configuration: Web Configuration
The logger / controller with socket for internal I/O expansion bus (eg. Relay module) is programmed with simple logic functions IF-THEN-ELSE, AND and OR simplifies the setup supports SNMP, SMTP , FTP, Modbus RTU and DCON Ethernet 10/100/1000Mbit setup via the integrated Web server 2 x RS232 ports 2 x RS485 ports
Clearance Ethernet I/O med 12/6 isolerede I/O kanaler. Med tæller og Integreret WEB-server med nem Javaprogrammering. 12 kanalers DI, 2 kanalers DO, 2 kanalers tæller - Ethernet-based smart I/O Fjernmonitorering og -styring Supporterer Modbus, TCP/IP, UDP, HTTP, DHCP Web-Server: XML, HTML 5, Java Script
Network module with digital I / O Korenix JETI / O 6550 Channels: 14/8 Digital inputs: 14 pcs., Logic 0: 0 - 4 V, Logic 1: 5 - 30V Digital outputs: & nbsp; 8 pcs. Open collector, 5 - 40 V 250mA Isolation: Optical 2500 VRMS for analog and digital inputs and outputs for the power supply Magnetic 1500 V from the network interface for the power supply 10/100 Mbit m / RJ45 their connector Operating temperature: - 25 ° C - 70 ° C Supports Modbus / TCP, OPC server, SNMP. Software included for configuration For DIN rail mounting Supply: 10 - 30 VDC via terminal block, Max 1.92 W